Scanner Configuration
The symbology properties below can be used with ScannerConfig or BTScannerConfig.
SymbologyProp_DEC_WINDOW_MODE
Turn on center decode mode
-
true -enables center decode mode
-
false - disables center decode mode (default)
SymbologyProp_TRIG_SCAN_MODE
Determines the scanner trigger mode.
-
oneShot - trigger enables one scan (default)
-
continuous - trigger continues scanning unique bar codes as long as pressed
SymbologyProp_DEC_EAN13_ENABLED
Enable decoding EAN-13 bar codes.
-
true - EAN-13 bar codes are decoded (default)
-
false - EAN-13 bar codes are not decoded
SymbologyProp_DEC_EAN13_CHECK_DIGIT_TRANSMIT
Enable check digit for EAN-13 bar code.
-
true - enable check digit (default)
-
false - disable check digit
SymbologyProp_DEC_EAN8_ENABLED
Enable decoding EAN-8 bar codes.
-
true - EAN-8 bar codes are decoded (default)
-
false - EAN-8 bar codes are not decoded
SymbologyProp_DEC_EAN8_CHECK_DIGIT_TRANSMIT
Enable check digit for EAN-8 bar code.
-
true - enable check digit (default)
-
false - disable check digit
SymbologyProp_DEC_UPCA_ENABLE
Enable decoding UPC-A bar codes.
-
true - UPC-A bar codes are decoded (default)
-
false - UPC-A bar codes are not decoded
SymbologyProp_DEC_UPCA_CHECK_DIGIT_TRANSMIT
Enable check digit for UPC-A bar code.
-
true - enable check digit (default)
-
false - disable check digit
SymbologyProp_DEC_UPCA_TRANSLATE_TO_EAN13
Enables conversion of UPC-A to EAN-13.
-
true - UPC-A is translated to EAN-13
-
false - UPC-A is not translated (default)
SymbologyProp_DEC_UPCA_NUMBER_SYSTEM_TRANSMIT
Enables transmission of the UPC-A number system.
-
true - UPC-A number system is transmitted (default)
-
false - UPC-A number system not transmitted
SymbologyProp_DEC_UPCE0_ENABLED
Enable decoding UPC-E bar codes.
-
true - UPC-E bar codes are decoded (default)
-
false - UPC-E bar codes are not decoded
SymbologyProp_DEC_UPCE_CHECK_DIGIT_TRANSMIT
Enable check digit for UPC-E bar code.
-
true - enable check digit (default)
-
false - disable check digit