Standard 2 of 5

Support for the parameters in the table is labeled as follows:

ü = Parameter is supported and available via the Scanner Options tab in the device profile.

X = Parameter is not supported on this device.

NYI = Not Yet Implemented. These parameters are considered unsupported, though they can (with knowledge) be set via the CCI or advanced settings.

A730 and A730x support for symbologies and parameters may differ. Refer to the table below for details.

The registry keys in the table below are located under:

[HKEY_LOCAL_MACHINE\Software\xxx\Imager\Standard 2 of 5]
Registry Key Default
Value
A730 A730x Description
Standard2of5Activation 0x0 ü ü Enables the Standard 2 of 5 symbology.
Standard2of5CodeMark 0x44 ü ü A single character inserted before the barcode data to indicate the symbology.
Standard2of5CheckDigitVerification 0x0 ü ü Enables modulo 10 calculation of check digits.
Standard2of5BarCodeLengthL1 0x6 ü ü Length value L1. Range is 0x0 to 0xFF (0 to 255).
Standard2of5BarCodeLengthL2 0x0 ü ü Length value L2. Range is 0x0 to 0xFF (0 to 255).
Standard2of5BarCodeLengthL3 0x0 ü ü Length value L3. Range is 0x0 to 0xFF (0 to 255).
Standard2of5BarCodeLengthMode 0x0 ü ü Length verification mode, where
0 = "L1 is min length",
1 = "L1, L2, L3 are fixed lengths" – Not supported on A730x,
2 = "L1 is min, L2 is max length".
Standard2of5CheckDigitTransmission 0x0 ü X Enable transmission of the check digit.
Standard2of5Format 0x0 ü ü Specifies read mode, where
0 = Identicon (6 start/stop bars) and
1 = Computer Identics (4 start/stop bars).
Standard2of5UDSI B5 ü ü User-defined symbology identifier. Range is 0-4 characters.