Code 11
Support for the parameters in the table is labeled as follows:
ü = Parameter is supported and available via the Scanner Options tab in the device profile.
X = Parameter is not supported on this device.
NYI = Not Yet Implemented. These parameters are considered unsupported, though they can (with knowledge) be set via the CCI or advanced settings.
A730 and A730x support for symbologies and parameters may differ. Refer to the table below for details.
The registry keys in the table below are located under:
[HKEY_LOCAL_MACHINE\Software\xxx\Imager\Code 11]
Registry Key | Default Value |
A730 | A730x | Description |
---|---|---|---|---|
Code11 |
0x0 | ü | ü | Enables the Code 11 symbology. |
Code11 |
0x2a | ü | ü | A single character inserted before the barcode data to indicate the symbology. |
Code11 |
0x1 | ü | ü | Number of check digits to verify. Range is 1 to 2. |
Code11 |
0x4 | ü | ü | Length value L1. Range is 0x0 to 0xFF (0 to 255). |
Code11 |
0x0 | ü | ü | Length value L2. Range is 0x0 to 0xFF (0 to 255). |
Code11 |
0x0 | ü | ü | Length value L3. Range is 0x0 to 0xFF (0 to 255). |
Code11 |
0x0 | ü | ü | Length verification mode, where 0 = "L1 is min length", 1 = "L1, L2, L3 are fixed lengths", – Not supported on N6600 2 = "L1 is min, L2 is max length". |
Code11 |
0x1 | ü | ü | Enable transmission of the check digit. |
Code11 |
C1 | ü | ü | User-defined symbology identifier. Range is 0-4 characters. |