Mounting the SRX2/SRX3 Battery Chargers

You need:

  • Drill
  • Fasteners
  • Screw driver
  • DIN rail, slotted steel 35 mm X 15 mm, Honeywell Part #CM-1000-20-101 or customer-supplied DIN rail meeting the following specifications :
Number of chargers on rail Minimum cut lengths for rail DIN rail specs Standard DIN rail
1 550 mm Single unit length 550 mm; weight 331.5 g (11.6933 oz)
2 1101 mm
3 1652 mm
  1. Install the DIN rail on the wall in the desired location. Ensure that the secure installation, supporting surface, and mounting hardware safely supports the weight of a fully loaded charger, at 25 lbs. per linear foot (37.2 kg/m) of DIN rail. Ensure that the anchor holes are at least 12 inches (30.5 cm.) from the floor. Verify that the installation meets all local building codes.
    The power supply for the charger should already be zip-tied in the back of the charger chassis. If it is not, plug the power supply into the charger and secure it. Do not plug it into a power source until after mounting is complete.
  2. Before attaching the charger to the rail, open the locking arms on the back of the unit by rotating the two levers out on each side of the charger. The arms are parallel to the floor in the unlocked position.
  3. Attach the charger to the DIN rail by hanging the two hooks on the back of the unit on the top lip of the rail.
  4. Slide the charger horizontally to the desired position on the rail, and rotate the locking arms into the locked position - flush with both sides of the unit.
  5. If the charger does not feel secure on the rail, adjust the rubber stops on the back of the unit by screwing them out toward the wall.
  6. Plug the power supply into a power source and check the LED indicator at the bottom right of the charger face. If the indicator light is a solid green, the charger is powered on.